Considering that all profile points are in one plane (the laser plane), determining the position and rotation angle of this system becomes fairly simple: correlating the measured profile of well-known object with the expected profile. This is where a calibration fixture comes in.


A calibration fixture is an object with a well-known and stable geometry that allows the calculation of rotation and offset for each head.

...

Figure 6. Example of a calibration fixture.

There is no single calibration fixture suitable for all scanning zone layouts, but JoeScan Support can help you find an economical and accurate design for your purposes. It is advisable to keep the original fixture so you can perform routine calibration checks.


The physical mounting of your scanners must be done in such a way that the calibration remains stable during operation.

...